AC inrush current (max.) |
COLD START 30A/115VAC 60A/230VAC |
Over Load Protection |
105 ~ 150% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed |
Over voltage Protection |
6.25 ~ 7.25V, 15.6 ~ 18V, 31.2 ~ 36V, 57.6 ~ 64.8V
Protection type : Shut down o/p voltage, re-power on to recover |
Withstand Voltage |
I/P-O/P:3KVAC
I/P-FG:2KVAC
O/P-FG:0.5KVAC |
Working Temperature |
-20 ~ +70℃ (Refer to "Derating Curve") |
Safety standards |
UL508, UL62368-1, TUV EN62368-1,Class I, Div. 2 Group A, B, C, D Hazardous Locations T4, EAC TP TC 004,
BSMI CNS14336-1, AS/NZS 60950.1 approved |
EMC EMISSION |
Compliance to EN55032 (CISPR32), EN61204-3 Class B, EN61000-3-2,-3, EAC TP TC 020, CNS13438 Class B |
EMC IMMUNITY |
Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11, EN55024, EN61000-6-2, EN61204-3, heavy industry level, criteria A, EAC TP TC 020 |
MTBF |
299.2K hrs min. MIL-HDBK-217F (25℃) |
Packing |
0.33Kg; 42pcs/14.8Kg/0.82CUFT |