E-Star Power Supply Mail to Us power supply products
| AC DC Power Supply | | Medical Power Supply | | DC DC Power Supply | | AC POWER CORD | - | Contact Us | - | Home |
 
AC DC Power Supply
> Din Rail Power Supply
> 85~100W
> HDR-100
 
 
 
 
 
AC DC Power Supply > Din Rail Power Supply > 85~100W > HDR-100
Power Supply HDR-100
Features : * Ultra slim design with 70mm (4SU) width
* Universal input 85~264VAC (277VAC available)
* No load power consumption<0.3W
* Isolation class II
* Pass LPS (Limited power source) for Blank type
* DC output voltage adjustable
* Protections: Short circuit/ Overload/ Over voltage
* Cooling by free air convection (working temperature: -30~+70°C)
* DIN rail TS-35/7.5 or 15 mountable
* Over voltage category III
* LED indicator for power on
* 3 years warranty
Model No. : HDR-100
AC input voltage range 85 ~ 264VAC (277VAC available ) 120 ~ 370VDC (390VDC available )
AC inrush current (max.) COLD START 35A/115VAC 70A/230VAC
Over Load Protection HDR-100 : 102 ~ 110% rated output power ; HDR-100-xxN : 105 ~ 150% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Over voltage Protection 14.2 ~ 16.2V, 18.8 ~ 22.5V, 30 ~ 36V, 56.5~ 64.8V
Protection type : Shut down o/p voltage, re-power on to recover
Withstand Voltage I/P-O/P:3KVAC
Working Temperature -30 ~ +70℃ (Refer to "Derating Curve")
Safety standards UL62368-1, UL508, TUV EN61558-2-16, IEC62368-1, EAC TP TC 004, BSMI CNS14336-1 approved; Design refer to TUV EN62368-1
EMC EMISSION Parameter Standard Test Level / Note
Conducted EN55032(CISPR32), CNS13438 Class B
Radiated EN55032(CISPR32), CNS13438 Class B
Harmonic Current EN61000-3-2 Class A
Voltage Flicker EN61000-3-3 ---
EMC IMMUNITY EN55024, EN55035, EN61000-6-2, EN61204-3
Parameter Standard Test Level / Note
ESD EN61000-4-2 Level 3, 8KV air; Level 2, 4KV contact, criteria A
Radiated Field EN61000-4-3 Level 3, criteria A
EFT / Burst EN61000-4-4 Level 3, criteria A
Surge EN61000-4-5 Level 4,2KV/L-N, criteria A
Conducted EN61000-4-6 Level 3, criteria A
Magnetic Field EN61000-4-8 Level 4, criteria A
Voltage Dips and Interruptions EN61000-4-11 >95% dip 0.5 periods, 30% dip 25 periods,
>95% interruptions 250 periods
MTBF 856.5K hrs min. MIL-HDBK-217F (25℃)
Packing 0.27Kg; 48pcs/14Kg/1.10CUFT
Dimension 70*90*54.5mm (W*H*D)
HDR-100 / 100W Ultra Slim Step Shape DIN Rail
Model No. DC VOLTAGE CURRENT RANGE RATED POWER VOLTAGE TOLERANCE R. & N. Effi.
HDR-100-12 12V 0 ~ 7.1A 85.2W ±2% 120mV 88%
HDR-100-12N 12V 0 ~ 7.5A 90W ±2% 120mV 88%
HDR-100-15 15V 0 ~ 6.13A 92W ±1% 120mV 89%
HDR-100-15N 15V 0 ~ 6.5A 97.5W ±1% 120mV 89%
HDR-100-24 24V 0 ~ 3.83A 92W ±1% 150mV 90%
HDR-100-24N 24V 0 ~ 4.2A 100.8W ±1% 150mV 90%
HDR-100-48 48V 0 ~ 1.92A 92.2W ±1% 240mV 90%
HDR-100-48N 48V 0 ~ 2.1A 100.8W ±1% 240mV 90%
 
Download PDF Here
< back >
 
--- E-Star Power Development Co., Ltd.