AC Inrush Current (Typ.) |
Cold start, 30A / 115VAC, 60A at 230VAC |
Overload protection |
105%~150% rated output power
Hiccup mode, recovers automatically after fault
condition is removed |
Over voltage protection |
CH1: 14.49~18.63V, CH1:28.98 ~ 37.26V
Hiccup mode, recovers automatically after fault
condition is removed |
Withstand voltage |
I/P-O/P: 3KVAC,
I/P-FG: 2KVAC,
O/P-FG: 0.5KVAC |
Working temperature |
-20°C ~ +70°C (Refer to output load derating
curve) |
Safety standards |
UL62368-1, TUV EN62368-1, EAC TP TC 004 approved |
EMC EMISSION |
Compliance to EN55032 (CISPR32) Class B, EN61000-3-2,-3, EAC TP TC 020 |
EMC IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A, EAC TP TC 020 |
Packing |
589.7K hrs min. MIL-HDBK-217F (25℃) |
Dimension |
PCB:101.6*50.8*29mm (L*W*H) ;
Enclosed type:103.4*62*37mm (L*W*H) |
PACKING |
PCB:0.13Kg; 96pcs/13.5Kg/0.89CUFT ;
Enclosed type:0.29Kg; 45pcs/14Kg/0.67CUFT |