INRUSH CURRENT (Typ.) |
COLD START 35A/115VAC 70A/230VAC |
Overload protection |
105%~150% rated output power
Protection type : Hiccup mode, recovers automatically
after fault condition is removed |
Over voltage protection |
CH1: 14.49~18.63V, CH1:28.98 ~ 37.26V
Protection type : Shut down o/p voltage, re-power
on to recover |
Working temperature |
-20 ~ +70°C (Refer to "Derating Curve") |
Safety standards |
UL62368-1, TUV EN62368-1, EAC TP TC 004 approved |
Withstand voltage |
I/P-O/P: 3KVAC,
I/P-FG: 2KVAC,
O/P-FG: 0.5KVAC |
EMC EMISSION |
Compliance to EN55032 (CISPR32) Class B, EN61000-3-2,-3, EAC TP TC 020 |
EMC IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A, EAC TP TC 020 |
MTBF |
257K hrs min. MIL-HDBK-217F (25℃) |
Packing |
PCB:0.35Kg;42pcs/15.7Kg/1.22CUFT ;
Enclosed type: 0.45Kg;32pcs/15.4Kg/0.94CUFT |
Dimension |
PCB:152.4*76.2*32mm (L*W*H) ;
Enclosed type:155.4*85*37mm (L*W*H) |