AC input voltage
range |
85 ~ 264VAC , 120 ~ 370VDC |
Over Load |
90 ~ 110% rated output power
Protection type : Constant current limiting recovers automatically after fault condition is removed |
Short Circuit |
Protection type : Hiccup mode, recovers automatically after fault condition is removed |
Over Voltage protection |
14 ~ 16.5V, 29 ~ 33V, 59 ~ 69V
Protection type : Shut down o/p voltage, re-power
on to recover |
Over Temperature |
100°C±10°C (RTH2) detect on inside ambient temperature
Protection type : Shut down o/p voltage, re-power on to recover |
Working temperature |
-30 ~ +70°C (Refer to output load derating
curve) |
Safety standards |
UL1012 (FOR GC120AXX-AD1 Only), TUV EN62368-1, PSE J60950-1, EAC TP TC 004 approved |
EMC EMISSION |
Compliance to EN55032 class B, FCC PART 15 / CISPR22 class B,CAN ICES-3(B)/NMB-3(B), EN61000-3-2,3, EAC TP TC 020 |
EMC IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A, EAC TP TC 020 |
MTBF |
400.7Khrs min. MIL-HDBK-217F(25℃) |
PACKING |
0.62Kg; 20pcs/13.4Kg/0.9CUFT |